From 3311e7120baeb2779eb17291acc96eefc9727468 Mon Sep 17 00:00:00 2001 From: "W. Trevor King" Date: Mon, 27 May 2013 08:34:53 -0400 Subject: [PATCH] calibcant/procedure.tex: Use a colon to introduce eq:limited-linear-surface Thanks Mom! --- src/calibcant/procedure.tex | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/src/calibcant/procedure.tex b/src/calibcant/procedure.tex index 9f92222..ce8717f 100644 --- a/src/calibcant/procedure.tex +++ b/src/calibcant/procedure.tex @@ -48,7 +48,7 @@ during this approach--retract cycle is analyzed to measure $\sigma_p$ The retraction data is analyzed using a similar approach to \pypiezo's surface detection algorithm to extract the slope of the contact region. Where \pypiezo\ uses a bilinear model -(\cref{eq:bilinear-surface}), \calibcant\ uses a limited linear model. +(\cref{eq:bilinear-surface}), \calibcant\ uses a limited linear model: \begin{equation} d(z) = \begin{cases} -- 2.26.2