From: W. Trevor King Date: Wed, 8 May 2013 03:06:33 +0000 (-0400) Subject: root.bib: Confirmation from Bechhoefer about missing 1/pi in A12 X-Git-Tag: v1.0~233 X-Git-Url: http://git.tremily.us/?a=commitdiff_plain;h=b789e4584a7d2b8618769ad7f99f0854c8adc843;p=thesis.git root.bib: Confirmation from Bechhoefer about missing 1/pi in A12 On Tue, May 07, 2013 at 07:19:32PM -0700, John Bechhoefer wrote: > Right you are! And you are the first person in > 10 years to catch > this :) --- diff --git a/src/root.bib b/src/root.bib index c87d9b0..5f39dac 100644 --- a/src/root.bib +++ b/src/root.bib @@ -1356,11 +1356,13 @@ keywords = "student experiments; safety; radiation pressure; laser beam applications", note = {Good discussion of the effect of correlation time on - calibration. Excellent detail on power spectrum derivation and - thermal noise for extremely overdamped oscillators in Appendix A - (references \citet{rief65}), except that their equation A12 is - missing a factor of $1/\pi$. References work on deconvolving - thermal noise from other noise\citep{cowan98}.}, + calibration. References work on deconvolving thermal noise from + other noise\citep{cowan98}. Excellent detail on power spectrum + derivation and thermal noise for extremely overdamped + oscillators in Appendix A (references \citet{rief65}), except + that their equation A12 is missing a factor of $1/\pi$. I + pointed this out to John Bechhoefer and he confirmed the + error.}, project = "Cantilever Calibration" }