From: W. Trevor King Date: Tue, 14 May 2013 03:24:20 +0000 (-0400) Subject: calibcant/procedure.tex: Add a calibcant/pyafm stack figure X-Git-Tag: v1.0~204 X-Git-Url: http://git.tremily.us/?a=commitdiff_plain;h=3dabfc7e65967b83562ad089294dc13d2bcdba59;p=thesis.git calibcant/procedure.tex: Add a calibcant/pyafm stack figure Make the parallel with the stack used by unfold-protein painfully obvious by duplicating the figure with a differend greyed-out brain module. --- diff --git a/src/calibcant/procedure.tex b/src/calibcant/procedure.tex index 840db0a..2b3f61e 100644 --- a/src/calibcant/procedure.tex +++ b/src/calibcant/procedure.tex @@ -7,7 +7,72 @@ buffer temperature $T$ with a thermocouple, and measuring thermal vibration when the tip is far from the surface to extract the fit parameters $G_{1f}$, $f_0$, and $\beta_f$. I've written the \calibcant\ package to carry out this calibration procedure, building -on packages in the \pyafm\ stack (\cref{fig:pyafm:stack}). +on packages in the \pyafm\ stack (\cref{fig:calibcant:stack}). + +\begin{figure} + \begin{tikzpicture}[decoration={ + markings,% switch on markings + mark=% add a mark for screw threading + between positions 0 and 1 step 1pt + with + { + \draw (0, 2pt) -- (1pt, -2pt); + } + } + ] + \tikzstyle{every node}=[text depth=0pt, rounded rectangle, + draw=blue!50, very thick, minimum height=1.7em] + \node[shape=rectangle,draw=none,inner sep=0] + (image) at (0,0) { + \asyinclude{figures/schematic/afm}}; + \node[shape=rectangle,draw=black, semithick] + (daq) at ($(image.south west) + (-0.5, -1)$) {DAQ card}; + \node[shape=rectangle,draw=black, semithick] + (motor) at ($(image.south) + (0, -1)$) {motor}; + %\draw[ + \coordinate (thermocouple) at ($(image.west) + (1, -4pt)$); + \node (pycomedi) at ($(daq) + (-5,0)$) {pycomedi}; + \node (pypiezo) at ($(pycomedi) + (0,1)$) {pypiezo}; + \node (pyafm) at ($(pypiezo) + (0,1)$) {pyafm}; + \node[black!20] (unfold-protein) at ($(pyafm) + (0,1)$) {unfold-protein}; + \node (stepper) at ($(pycomedi) + (2,1)$) {stepper}; + \node (pypid) at ($(stepper) + (2,0)$) {pypid}; + \node (h5config) at ($(pycomedi) + (-3,0)$) {h5config}; + \node (calibcant) at ($(unfold-protein) + (-3,0)$) {calibcant}; + \draw (pypiezo) -- (pyafm); + \draw (stepper) -- (pyafm); + \draw (pypid) -- (pyafm); + \draw[black!20] (pyafm) -- (unfold-protein); + \draw (h5config) -- (pypiezo); + \draw (h5config) -- (pyafm); + \draw[black!20] (h5config) -- (unfold-protein); + \draw (pyafm) -- (calibcant); + \draw (h5config) -- (calibcant); + \draw[purple] (pypid) -- (thermocouple); + % begin thermometer symbol + \draw[blue!20, line width=4pt, cap=round] + (thermocouple) -- ($(thermocouple) + (0,12pt)$); + \fill[blue!20] (thermocouple) circle (5pt); + \draw[red, line width=2pt, cap=butt] + (thermocouple) -- ($(thermocouple) + (0,8pt)$); + \fill[red] (thermocouple) circle (4pt); + % end thermometer symbol + % begin motor screw + \draw[black!20, line width=4pt] + (motor) -- (image.south); % shaft with decoration threads + \draw[black, decorate, ultra thin] + (motor) -- (image.south); % shaft with decoration threads + % end motor screw + \draw[red] + (pypiezo) -- (pycomedi) -- (daq) -- ($(image.south) + (-6pt, 0)$); + \draw[red, line width=2pt] (pycomedi) -- (daq); + \draw[blue] (stepper) -- (pycomedi) -- (daq) -- (motor); + \end{tikzpicture} + \caption{Dependency graph for \calibcant, which shares the + \pyafm\ stack with \unfoldprotein. Only the ``brain'' module + changed with respect to + \cref{fig:pyafm:stack}.\label{fig:calibcant:stack}} +\end{figure} \subsection{Photodiode calibration} \label{sec:calibcant:bump}