root.bib: Confirmation from Bechhoefer about missing 1/pi in A12
authorW. Trevor King <wking@tremily.us>
Wed, 8 May 2013 03:06:33 +0000 (23:06 -0400)
committerW. Trevor King <wking@tremily.us>
Wed, 8 May 2013 03:06:33 +0000 (23:06 -0400)
On Tue, May 07, 2013 at 07:19:32PM -0700, John Bechhoefer wrote:
> Right you are!  And you are the first person in > 10 years to catch
> this :)

src/root.bib

index c87d9b01af1bc359b5826cddccdb07e6ea30725a..5f39dacf6e7ce90c3cf3f3afb91348059f8ea7d5 100644 (file)
     keywords = "student experiments; safety; radiation pressure; laser beam
         applications",
     note = {Good discussion of the effect of correlation time on
-      calibration.  Excellent detail on power spectrum derivation and
-      thermal noise for extremely overdamped oscillators in Appendix A
-      (references \citet{rief65}), except that their equation A12 is
-      missing a factor of $1/\pi$.  References work on deconvolving
-      thermal noise from other noise\citep{cowan98}.},
+      calibration.  References work on deconvolving thermal noise from
+      other noise\citep{cowan98}.  Excellent detail on power spectrum
+      derivation and thermal noise for extremely overdamped
+      oscillators in Appendix A (references \citet{rief65}), except
+      that their equation A12 is missing a factor of $1/\pi$.  I
+      pointed this out to John Bechhoefer and he confirmed the
+      error.},
     project = "Cantilever Calibration"
 }