Update MultiMode references in general posts.
authorW. Trevor King <wking@drexel.edu>
Fri, 19 Nov 2010 18:19:47 +0000 (13:19 -0500)
committerW. Trevor King <wking@drexel.edu>
Fri, 19 Nov 2010 18:19:47 +0000 (13:19 -0500)
posts/Grr_Multimodes.mdwn
posts/MultiMode.mdwn
posts/MultiMode/internals.rst
posts/MultiMode/stepper.mdwn
posts/MultiMode_head_connection_deconstructed.mdwn
posts/Stripchart.mdwn

index 7f605f6f7b690b86ac76cecb62dd3ba33af81c0a..b4092b1ce0a8236b4f38dd1083cb66d59cce5350 100644 (file)
@@ -1,26 +1,28 @@
-[[!meta  title="Grr Multimodes"]]
+[[!meta  title="Grr MultiModes"]]
 [[!meta  date="2008-07-07 18:54:09"]]
-There was some trouble with tapping-mode imaging this morning, and with Prof.
-Yang's help things seem to be straightened out now.  I tried both Nanoscopes
-with both Multimodes (we have two *nominally* identical systems), but had not
-bothered to swap heads.  As it turned out, we had been using the infrared head
-(we have three heads), which wasn't working.  Not that that was the only
-problem.  As it turned out, tapping seems to be working with the combination
-<pre>
-  Nanoscope 2 -- Multimode 1 -- Head 1 or 2
-</pre>
 
-As far as I can tell, the problem is generating the voltage for the piezo that
-vibrates the cantilever, which seems to take place
-[on the Multimode main board](http://www.physics.drexel.edu/~wking/rsrch/multimode/internals.shtml).  Unless
-something is seriously wrong with the Nanoscope, it shouldn't matter which
-Nanoscope we use.  I suppose I should trace the Nanoscope-Multimode
+There was some trouble with tapping-mode imaging this morning, and
+with Prof.  Yang's help things seem to be straightened out now.  I
+tried both NanoScopes with both [[MultiModes|MultiMode]] (we have two
+*nominally* identical systems), but had not bothered to swap heads.
+As it turned out, we had been using the infrared head (we have three
+heads), which wasn't working.  Not that that was the only problem.  As
+it turned out, tapping seems to be working with the combination
+
+    NanoScope 2 -- MultiMode 1 -- Head 1 or 2
+
+As far as I can tell, the problem is generating the voltage for the
+piezo that vibrates the cantilever, which seems to take place on the
+[[MultiMode main board|MultiMode/internals]].  Unless something is
+seriously wrong with the NanoScope, it shouldn't matter which
+NanoScope we use.  I suppose I should trace the NanoScope-MultiMode
 communication in both cases and look for something different.
 
-I've no idea how generating a tunable sine wave can be so complicated.  The
-simple solution is to stick to *modular* equipment with open-standard,
-easily-accessible communication between them, but I don't have time to develop
-a system like that.  Some day I will give up on Nanoscope troubleshooting and
-build a [GXSM system](http://gxsm.sourceforge.net/).
+I've no idea how generating a tunable sine wave can be so complicated.
+The simple solution is to stick to *modular* equipment with
+open-standard, easily-accessible communication between them, but I
+don't have time to develop a system like that.  Some day I will give
+up on NanoScope troubleshooting and build a [GXSM
+system](http://gxsm.sourceforge.net/).
 
 [[!tag tags/hardware]]
index f9b874710a7c8cd1f3299449c21fa37be165624b..734488b5080e12f6feec4a2f22746901b40e9d4b 100644 (file)
@@ -1,4 +1,4 @@
-The Multimode product line has been passed through several companies
+The MultiMode product line has been passed through several companies
 over the years.  It started out at [Digital Instruments][DI], which
 was aquired by [Veeco][] in February 1998 before being passed off to
 [Bruker][] in August 2010.
@@ -15,8 +15,8 @@ notes on:
 * A [MultiMode manual][manual]
 
 [[!img multimode_assembled.jpg size="500x"
-  alt="An assembled Multimode microscope"
-  title="An assembled Multimode microscope"]]
+  alt="An assembled MultiMode microscope"
+  title="An assembled MultiMode microscope"]]
 
 [DI]: http://www.di.com/
 [Veeco]: http://www.veeco.com/
index 1d6179b23c10e798f843f16666cba1d0e3018dd7..6083aa98c86939f49827a3faf830c890eeaf33e0 100644 (file)
@@ -172,7 +172,7 @@ Line  Role                                                           To
 AFM head to tipholder line descriptions
 =======================================
 
-Labeled looking down on tipholder along laser, with Multimode LCD at
+Labeled looking down on tipholder along laser, with MultiMode LCD at
 bottom from top-left: 1 2 3/4 5 6
 
 ====  =====================  =================================================================
index 392cfd4643b213b42bfbae2c898348105db87b93..a9c73117f2d3684b7f37471d638c050cc8c781a5 100644 (file)
@@ -21,7 +21,7 @@ some of the more suspicious lines on an oscilloscope, I saw that lines
 they were TTL compatible.  A short while later (wink), the LabVIEW
 code was up and running.  The LabVIEW computer (via a PCI-6052E card
 and BNC-2090 box) writes TTL stepper motor currents to the relevent
-lines on the Nanoscope↔Multimode cable using our break-in box.
+lines on the Nanoscope↔MultiMode cable using our break-in box.
 
     Computer <-> Breakout box <-> MultiMode
     NanoScope <------^
@@ -33,7 +33,7 @@ Part list (outdated commercial parts linked to the current generation):
 * [BNC-2090](http://sine.ni.com/nips/cds/view/p/lang/en/nid/1177)
 * Nanoscope IIIa (altered)
 * Homemade break in box
-* [[Multimode II AFM]]
+* [[MultiMode II AFM]]
 
 Breakout box
 ------------
@@ -42,8 +42,8 @@ Build a DB-25 breakout box, such as the ugly hack job shown
 below. This gives us access to the stepper motor drive-lines.
 
 [[!img break_in_box.jpg size="500x"
-  alt="Break in box for Nanoscope-Multimode cable"
-  title="Break in box for Nanoscope-Multimode cable"]]
+  alt="Break in box for Nanoscope-MultiMode cable"
+  title="Break in box for Nanoscope-MultiMode cable"]]
 
 Control the motor
 -----------------
@@ -69,7 +69,7 @@ pseudo-code:
       write( output[index] );
     }
 
-For my Multimode, the motor steps 'Up' when I equate:
+For my MultiMode, the motor steps 'Up' when I equate:
 
 <table>
   <tr><th>DB-25</th><th>Role</th></tr>
@@ -89,12 +89,12 @@ Figuring it out
 ===============
 
 [[!img multimode_interior_0.jpg size="500x"
-  alt="The interior of the Multimode chassis with the main PCB removed"
-  title="The interior of the Multimode chassis with the main PCB removed"]]
+  alt="The interior of the MultiMode chassis with the main PCB removed"
+  title="The interior of the MultiMode chassis with the main PCB removed"]]
 
 [[!img multimode_main_board_chips.jpg size="500x"
-  alt="The main board of the Multimode"
-  title="The main board of the Multimode"]]
+  alt="The main board of the MultiMode"
+  title="The main board of the MultiMode"]]
 
 General stepper motor wiring
 ----------------------------
index 5b43215d294ffa088352f5b6b6649ffb5376e5e8..b6c86fe7cee08ae14dabaa94a347aca2e23b7e3a 100644 (file)
@@ -1,11 +1,11 @@
 [[!meta  title="MultiMode head connection deconstructed"]]
 [[!meta  date="2008-07-15 17:48:17"]]
-After some tapping-mode debugging, I now know what *almost* all the lines
-connecting the
-[MultiMode head](http://www.physics.drexel.edu/~wking/img/multimode/multimode_head.jpg)
-to the
-[base](http://www.physics.drexel.edu/~wking/img/multimode/multimode_base_0.jpg)
-do.  Take a look at my [notes](http://www.physics.drexel.edu/~wking/rsrch/multimode/internals.shtml#head).
+
+After some tapping-mode debugging, I now know what *almost* all the
+lines connecting the [[MultiMode]] head ([[!ltio
+MultiMode/multimode_head.jpg]]) to the base ([[!ltio
+MultiMode/multimode_base_0.jpg]]) do.  Take a look at my
+[[notes|MultiMode/internals#afm-head-micro-d-15-connector-line-descriptions]].
 
 If anyone has figured out line 4, or is using a MultiMode as an STM, please
 [send me an email](http://www.physics.drexel.edu/~wking/contact.shtml).
index e3e072cd56ef4f60654c121701ca9f1e48b44ed8..ada479b003d1b3656af57ee410e9f6c81d224c19 100644 (file)
@@ -1,8 +1,8 @@
 [[!meta  title="Stripchart"]]
 [[!meta  date="2008-07-08 17:03:08"]]
-I was trying to troubleshoot the feedback loop on our Nanoscope today, and
+I was trying to troubleshoot the feedback loop on our NanoScope today, and
 when I went to fire up my [Comedi](http://www.comedi.org/)-driven stripcharts
-monitoring some lines in the DB-25 cable connecting the Multimode to the
+monitoring some lines in the DB-25 cable connecting the [[MultiMode]] to the
 Nanoscope, I got a bunch of wierd errors (errnos 11 and 29).  I tracked them
 down to some of the Xlib function calls in my stripchart code (yes, I wrote my
 own