+ * This part of the demo measures channels 1, 2, 3, 4 at a rate of
+ * 10 khz, with the inter-sample time at 10 us (100 khz). The number
+ * of scans measured is 10. This is analogous to the old mode2
+ * acquisition.
+ */
static void do_cmd_1(comedi_t *dev)
{
comedi_cmd cmd;
* events occur periodically at a rate of scan_begin_arg
* nanoseconds between scans. */
cmd.scan_begin_src = TRIG_TIMER;
- cmd.scan_begin_arg = 1000000; /* in ns */
+ cmd.scan_begin_arg = 100000; /* in ns */
/* The timing between each sample in a scan is controlled
* by convert. Like above, TRIG_TIMER specifies that
* convert events occur periodically at a rate of convert_arg
* nanoseconds between scans. */
cmd.convert_src = TRIG_TIMER;
- cmd.convert_arg = 100000; /* in ns */
+ cmd.convert_arg = 10000; /* in ns */
/* The end of each scan is almost always specified using
* TRIG_COUNT, with the argument being the same as the